Ground Alarm Photovoltaic Inverter
If the inverter displays the event numbers 3501, 3601 or 3701, there could be a ground fault. The electrical insulation from the PV system to ground is defective or insufficient. [pdf]FAQS about Ground Alarm Photovoltaic Inverter
Do solar inverters need a ground fault detection & interruption device?
Solar inverters must have a ground fault detection and interruption (GFDI) device to detect and stop ground faults. It can identify the ground fault, generate an error code, and shut down the inverter. The amount of current flowing through the ground fault required to trip the inverter's GFDI varies based on the inverter type.
What is a DC ground fault in a PV system?
DC ground faults are the most common type of fault in PV systems and half go undetected. A DC ground fault is the undesirable condition of current flowing through the equipment grounding conductor in the circuits carrying DC power (before the inverter).
How can a DC inverter prevent a ground fault?
DC ground faults can be prevented using transformer-less (non-isolated) inverters, which 1) have sensitive electronics that can sense a fault as low as 300 mA and 2) do not have a grounded conductor, thus reducing the possibility of unintended current to ground.
What is a ground fault in a PV system?
A ground fault is an unintentional connection between a current-carrying conductor and a grounded metal part. On the DC side of a PV array, ground faults typically occur on either the positive or negative wire. They can also happen on one of the ungrounded conductors (L1, L2, or L3) on the AC side of the system.
How do you fix a ground fault in a PV system?
Replace all impacted equipment and conductors. Ground faults can be a persistent issue for any PV system. They take a toll on system health and productivity. A clear, consistent approach to finding and diagnosing such faults can help you repair them reliably and efficiently whenever they occur.
What is a ground fault in a solar system?
Ground faults can be a frequent and persistent issue for any size solar installation or photovoltaic (PV) array. They can impact system health and reduce productivity. Every solar technician needs to know what they are, how to find them, and how to repair them efficiently. What is a ground fault?

Photovoltaic grid-connected inverter ground wire
Ground fault detection (GFCI) will cause the AC power to trip when it detects unequal currents flowing through the positive (live) and neutral conductors. The fault detection assumes. . Inverters are enclosed with an Aluminum heatsink to dissipate heat and are also fitted with a grounding terminal to the enclosure. A grounding wire of 6 AWG must be connected to the grounding terminal on the inverter. . The grounding of inverters in off-grid installations can be critical to the safety of the users and the connected AC-powered devices. Correct. [pdf]